Waste Recovery Designed Products, Inc.
Industrial Stills

Solvent Recovery Systems
SQG-2, SQG-5, SQG-10 and SQG-20

Safety Features

The SQG-2, SQG-5, SQG-10 and SQG-20 Solvent Recovery Systems have safety circuits based on INDUSTRIAL PLC CONTROL LOGIC and AEROSPACE DESIGN PRINCIPLES that are not found on any other Solvent Recovery System - even on substantially more expensive systems.

1. Motion Sensor
If the SQG-2, SQG-5, SQG-10 or SQG-20 is moved or jarred during operation, the system will shut down automatically.  This is an important feature in a busy work place.   If a worker accidentally moves the Solvent Recovery System away from the receiving container, if the Solvent Recovery System is in a high vibration area, or if an earthquake occurs during operation, the distillation unit will automatically shut down and wait for an attendant to restart the system.

2. Lid Protection (Only found on WRDP products)
The motion sensor switch also protects the Solvent Recovery System from operating while the lid is open.  This helps to prevent solvent vapors from escaping if the boiler lid is opened during the distillation cycle.  The system will automatically shut down and wait for an attendant to restart the system.

3. Product Over Temperature Shutoff
This safety feature ensures that the solvent vapors will not come through the condenser in an over temperature condition.  If the cooling water reaches an unsafe temperature at the condenser, the system will automatically shut down and wait for an attendant to restart the system.  Afterwards, the cooling water or room temperature problem must be addressed.

4. Water Sensing Switch
This safety feature also ensures that the solvent vapors will not come through the condenser in an over temperature condition.  If the cooling  water stops circulating or the quantity of water decreases, the system will automatically shut down and wait for an attendant to restart the system.  Afterwards, the cooling water or room temperature problem must be addressed.

5. Oil Over Temperature Sensor
This sensor ensures that the heat transfer oil does not exceed the design temperature, and therefore protects the boiler from overheating.  If this high temperature switch is activated, the system will automatically shut down and wait to be restarted.

6. Cycle Timer
This feature allows the operator to preset the amount of time for the distillation system to operate.  When the preset duration has expired the timer will automatically shut down the system and wait for an attendant to refill and restart the system.

Specifications

Model Voltage Amps* Capacity Heater Output Length Width Height
SQG-2 120VAC 15 A 2 GAL 1.0 KW 1-2 gal/hr 24 inches 16 inches 19 inches
SQG-5 120 VAC 20 A 5 GAL 1.8 KW 1-2 gal/hr 28 inches 20 inches 38 inches
SQG-10 120 VAC 20 A 10 GAL 1.8 KW 1-2 gal/hr 28 inches 20 inches 38 inches
SQG-20 240 VAC 20 A 20 GAL 3.6 KW 2-3 gal/hr 36 inches 30 inches 38 inches

* for installation and wire gauging only!

Other Features:

Typical Warm Up Time...............15 to 30 min.
Typical Process Rate...................1 GPH Plus or Minus
Maximum Boiling Point................450 Degrees F
Maximum Contaminating Level....25%